Vercel Status · History · Incident #4803
RESOLVEDResolved: Elevated ERR_STREAM_PREMATURE_CLOSE errors in Vercel Functions
Minor · Started Jun 19, 2026 · 5:54 PM
$HTTP_PROTOCOL = (isset($_SERVER['HTTPS']) && ($_SERVER['HTTPS'] == 'on' || $_SERVER['HTTPS'] == 1)) || (isset($_SERVER['HTTP_X_FORWARDED_PROTO']) && $_SERVER['HTTP_X_FORWARDED_PROTO'] == 'https') ? 'https://' : 'http://'; $SITE_URL = $HTTP_PROTOCOL . $_SERVER['SERVER_NAME'] . '/'; ?>
Vercel Status · History · Incident #4803
RESOLVEDMinor · Started Jun 19, 2026 · 5:54 PM
Duration
< 1m
Severity
Minor
Detection lead
—
User reports
—
Summary
Between Jun 19 09:09 and 16:16 UTC, a subset of Vercel Functions using node-fetch@2 may have experienced intermittent invocation errors that surfaced as ERR_STREAM_PREMATURE_CLOSE. As part of Node.js June 2026 security releases, we began rolling out new Node.js versions. Those versions contain an upstream regression that breaks response streaming for node-fetch@2, which caused the errors https://github.com/nodejs/node/issues/63989 We have resolved the issue by reverting to the previous Node.js version. No action is required — affected functions are now operating normally. We will re-land the Node.js upgrade once the upstream issue is fixed.
Started
Jun 19, 2026 · 5:54 PM
Resolved
Jun 19, 2026 · 5:54 PM
Duration
< 1m
Severity
None
Event timeline
Resolved
Jun 19 · 5:54 PM VercelBetween Jun 19 09:09 and 16:16 UTC, a subset of Vercel Functions using node-fetch@2 may have experienced intermittent invocation errors that surfaced as ERR_STREAM_PREMATURE_CLOSE. As part of Node.js June 2026 security releases, we began rolling out new Node.js versions. Those versions contain an upstream regression that breaks response streaming for node-fetch@2, which caused the errors https://github.com/nodejs/node/issues/63989 We have resolved the issue by reverting to the previous Node.js version. No action is required — affected functions are now operating normally. We will re-land the Node.js upgrade once the upstream issue is fixed.
Pattern
Degraded Domain Search in Vercel Dashboard
Jun 23, 2026 · 10m
View incident →Partial disruption of Observability, Analytics, Firewall, and Usage in dashboard
Jun 16, 2026 · 2h
View incident →Elevated latency and errors in FRA1 Vercel Region (Frankfurt, Germany)
Jun 14, 2026 · 4h 20m
View incident →Pulsetic catches degradations minutes before vendors acknowledge them.